Friday, November 15, 2013

BLISTERING IN INTERNAL FUSION BONDED EPOXY

All FBE coatings to be coated as per recommended temperature given in Technical Data Sheet (Data Sheet) of coating manufacturer.


If you apply FBE  at lower temperature, hopefully sooner or later your result will be also same as .......................



Blistering due to lower temperature issue in Internal FBE can happen during application of external fbe  or during its service life. In External FBE it can happen during its service life.

Localized blistering can also result due to presence of liquid or moisture in FBE powder spray system or  oil and grease on blasted surface. 